why choose thin film intumescents

Thin film intumescents have a number of advantages over other methods of fire rating. Some of these include

Installation

  • Relative to other materials, thin film intumescents are easy to apply on or off site
  • Application of thin film intumescent is considerably lighter than other methods such as fire spray or cladding, thus allowing considerations to be made with regards to steel used
  • Our thin film intumescents are water based. This means we can apply on-site with minimal interference to other trades, allowing timelines to be met.
  • We can achieve a range of FRL's from 30-120 minutes

Durability

  • Thin film intumescents are resistant to moisture and abrasion , increasing their longevity
  • Furthemore, they can be top coated with a range of compatible products, further protecting the surface

Application

  • Due to the low volume per lineal meter, thin film intumescents are quick to apply in comparison to alternative methods
  • They provide excellent coverage over most surface irregularities in structural steel elements
  • Application via specialised equipment leads to limited overspray and therefore limited wastage
    • This lowers costs and is better for the environment
  • Only qualified applicators can apply thin-film intumescents, giving you piece of mind that the work has been done correctly
  • Remedial are fully qualified (by independent bodies) in the application

Aesthetics

  • Thin film intumescents provide the ideal system for design and aesthetic finishes as desired by architects.
  • Where design criteria requires exposed structural steel elements, thin film intumscents provide the perfect answer as they can be top coated to provide a versatile range of aesthetic finishes including metallic finishes and high gloss industrial coatings

Maintenance

  • Thin Film Intumescents are extremely easy to keep clean as opposed to many other fire protection options
  • Post installation, repairs are relatively easy and can be done with a minimum of fuss and mess

Fire Rating Contact Us

Testing fire rated material applied to a steel beam Applying Thin film intumescents with specialised spray equipment

P&I Printing - Epoxy Floor Solution

P&I printers, located in Sydney's west required a floor that achieved both a non-slip rating whilst maintaining a highly appealing finish

read more

Narrabeen Sands - Commercial Kitchen Floor

The brand new Narrabeen Sands Hotel, recently opened in Sydney?s beachside suburb of Narrabeen, needed the correct floors to be laid.

read more

Stay Connected

Get our latest case studies, industry announcements and information delivered direct to you.

* Denotes required field
*
*
*
submit

Mineral Fibre Barrier Fire Rating Test Results

Independent fire rating testing body Branz recently conducted tests on Nullifire B747 used in combination with mineral fibre. The results were very pleasing